Image/Video Galleries
Wellgreen
Geological Model Videos:
-
3D Geological Block Model - Long Section
(Summer 2011) -
3D Geological Block Model - Plan View
(Summer 2011) -
Wellgreen Drillholes Wireframe - Plan View
(Summer 2011) -
Wellgreen Drillholes Wireframe - Section View
(Summer 2011)
Photo Gallery

Yukon Government Site Tour (Fall 2012) 
Yukon Government Site Tour (Fall 2012) 
Wellgreen Surface Drilling
(Aug 2012)
First Nation Meeting
(Aug 2012)
Underground Drilling
(Aug 2012)
Wellgreen Camp
(Aug 2012)
Wellgreen Surface Drilling
(June 2012)
Shakespeare
Photo Gallery

Shakespeare
(Sept 2012)
Shakespeare
(Sept 2012)
Shakespeare
(Sept 2012)
Shakespeare
(Sept 2012)
Shakespeare
(Sept 2012)
Shakespeare
(Sept 2012)
Shakespeare
(Sept 2012)-
Lynn Lake
Geological Model Video:
-
Lynn Lake Drillholes with Conceptual Modeling
(Summer 2011)
Plan View Video Image
(Summer 2011)
Section View Video Image, Looking North
(Summer 2011)
Section View Video Image, Looking West
(Summer 2011)
Photo Gallery
Drilling
(Sept 2010)
Cores
(Sept 2010)
Mine Housing
Mine Housing
Core Sample
Storage Area
Mine Rail Road -
Conferences and Events
Photo Gallery
New Orleans Investment Conference
(Oct 2012)
New Orleans Investment Conference
(Oct 2012)
2012 PDAC
(Mar 2012)
2012 PDAC
(Mar 2012)
Mineral resources that are not mineral reserves do not have demonstrated economic viability. Neither the TSX Venture Exchange nor its Regulation Services Provider (as that term is defined in the policies of the TSX Venture Exchange) accepts responsibility for the adequacy or accuracy of this website.
Qualified Person under NI 43-101
Danniel Oosterman, P.Geo., a consultant of the Company is the
qualified persons responsible for the technical information on this
website.
Cautionary Note Regarding Mineral Resources and Mineral Reserves
Readers should refer to the Company's current technical reports and
other continuous disclosure documents filed by the Company available
on Sedar at www.sedar.com for further information on the mineral
resource estimates of the Company's projects, which are subject to the
qualifications and notes set forth therein, as well as for additional
information relating to the Company more generally. Mineral resources
which are not mineral reserves, do not have demonstrated economic
viability. Inferred mineral resources have insufficient confidence to
allow the meaningful application of technical and economic parameters or
to enable an evaluation of economic viability suitable for public
disclosure. Neither the Company nor readers can assume that all or any
part of an inferred mineral resource will be upgraded to indicated or
measured mineral resource. Most projects at the inferred mineral
resource stage do not ever achieve successful commercial production.
Each stage of a project is contingent on the positive results of the
previous stage and that there is a significant risk that the results may
not support or justify moving to the next stage.
Quality Control and Quality Assurance
Prophecy Platinum executes a quality control program to ensure best
practice in sampling and analysis. Samples are cut and split for assay
with the remaining sample retained for reference. Blanks, Standard
Reference Material (SRM), and duplicates were inserted into the sample
stream every 20th sample. A duplicate sample is taken every 20th sample
of core. The selected sample is sawn in half and then sawn in half
again. The quartered core is then placed into two different sample bags
with different sample numbers and sealed. The SRM material comes from
Natural Resources Canada and Analytical Solutions Limited. These were
inserted into the sample stream immediately after the second duplicate.
The SRMs used are WMS-1a, WPR-1 and WGB-1. Sample Blanks are obtained
from two sources; granodiorite from a local quarry and garden marble
from hardware stores in Whitehorse, Yukon. A Blank sample is inserted
into the sample stream after the SRM. Assayed samples are transported
in sealed and secured bags for preparation at ALS Chemex Prep Lab
located in Whitehorse, Yukon. Pulverized (pulp) samples are shipped for
analysis to ALS Chemex Assay Laboratory in Vancouver, B.C. ALS Chemex
is an ISO/IEC 17025:2005 accredited laboratory and registered under ISO
9001:2000.
Quality assurance and quality control are monitored using scatterplots,
Thompson-Howarth plots and statistical analysis to ensure duplicates,
blanks and standard data are reliable and indicate robustness of
overall results. ALS Chemex quality-assurance procedures are also
included in this process."
Click here for the Qualified Person information, forward-looking statements and the cautionary note.
